Need a policy because of a recent regulatory change? We’ve got it for you. Need some quick training on a specific HR topic? We’ve got it for you. HR Insider provides the resources you need to craft, implement and monitor policies with confidence. Our team of experts (which includes lawyers, analysts and HR professionals) keep track of complex legislation, pending changes, new interpretations and evolving case law to provide you with the policies and procedures to keep you ahead of problems. FIND OUT MORE...
Hoist Safety – Capstan Fatality File

Employee killed in fall from telecommunications tower

Employees #1 and #2 were being hoisted up a 500 ft telecommunications tower to replace antenna parts damaged when the tower was struck by lightning. They were being raised by a 1/2 in. nylon rope load line using a friction winch. Employee #2 was attached to the load line by a pelican clip that was attached to a seat strap D-ring by a small clevis on his tree saddle safety belt. The pelican clip had been run through a hand-tied loop in the end of the rope load line. Employee #1 was attached to the same loop by the center clip of a short three-clip rope safety lanyard, as were the replacement antenna parts. The remaining clips were attached to the waist D-rings on her full body harness. The rope load line had been routed up the tower through a 3 in.

McKissik top block pulley that had been hand-tied to the face of the tower by two pieces of 1/2 in. climbing rope, at a height of approximately 475 ft. The 1/2 in. nylon load line was then routed back down the tower and through a heel block pulley attached near the base. The free end was then wrapped around a cathead (capstan hoist) which had been bolted to the left rear wheel of a small pick-up truck, with the wheel jacked up off the ground. With the pickup truck idling, Employee #3 manually pulled on the free end of the rope, hoisting Employees #1 and #2 up the tower. The two employees were at a height of approximately 385 ft when the pickup's engine apparently stalled. When a coworker tried to restart the engine, friction was lost between the rope load line and the capstan hoist drum, causing Employees #1 and #2 to fall. They struck a guy at a height of about 210 ft and managed to ride it to the ground. Employee #1 was killed. Employee #2 suffered a fractured back, a fractured jaw, some fractured ribs, and other internal injuries. Employee #3 sustained severe rope burns to both hands from trying to stop the rope.

Sources:Β Osha.gov/